Search Results (806 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2018-7809 1 Schneider-electric 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more 2024-11-21 N/A
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete function of the web server.
CVE-2018-7807 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A
Data Center Expert, versions 7.5.0 and earlier, allows for the upload of a zip file from its user interface to the server. A carefully crafted, malicious file could be mistakenly uploaded by an authenticated user via this feature which could contain path traversal file names. As such, it could allow for the arbitrary upload of files contained with the zip onto the server file system outside of the intended directory. This is leveraging the more commonly known ZipSlip vulnerability within Java code.
CVE-2018-7806 1 Schneider-electric 1 Struxureware Data Center Operation 2024-11-21 N/A
Data Center Operation allows for the upload of a zip file from its user interface to the server. A carefully crafted, malicious file could be mistakenly uploaded by an authenticated user via this feature which could contain path traversal file names. As such, it could allow for the arbitrary upload of files contained with the zip onto the server file system outside of the intended directory. This is leveraging the more commonly known ZipSlip vulnerability within Java code.
CVE-2018-7804 1 Schneider-electric 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more 2024-11-21 N/A
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing.
CVE-2018-7803 1 Schneider-electric 1 Triconex Tristation Emulator 2024-11-21 N/A
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant.
CVE-2018-7802 1 Schneider-electric 2 Evlink Parking, Evlink Parking Firmware 2024-11-21 N/A
A SQL Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could give access to the web interface with full privileges.
CVE-2018-7801 1 Schneider-electric 2 Evlink Parking, Evlink Parking Firmware 2024-11-21 8.8 High
A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed.
CVE-2018-7800 1 Schneider-electric 2 Evlink Parking, Evlink Parking Firmware 2024-11-21 N/A
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
CVE-2018-7799 1 Schneider-electric 1 Software Update Utility 2024-11-21 N/A
A DLL hijacking vulnerability exists in Schneider Electric Software Update (SESU), all versions prior to V2.2.0, which could allow an attacker to execute arbitrary code on the targeted system when placing a specific DLL file.
CVE-2018-7797 1 Schneider-electric 3 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Ecostruxure Power Scada Operation 2024-11-21 N/A
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site.
CVE-2018-7796 1 Schneider-electric 1 Powersuite 2 2024-11-21 N/A
A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.
CVE-2018-7793 1 Schneider-electric 4 Foxboro Dcs, Foxboro Evo, Foxview and 1 more 2024-11-21 N/A
A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission.
CVE-2018-7788 1 Schneider-electric 2 Modicon Quantum, Modicon Quantum Firmware 2024-11-21 6.5 Medium
A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection.
CVE-2018-7787 1 Schneider-electric 1 U.motion Builder 2024-11-21 N/A
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request.
CVE-2018-7786 1 Schneider-electric 1 U.motion Builder 2024-11-21 N/A
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.
CVE-2018-7785 1 Schneider-electric 1 U.motion Builder 2024-11-21 N/A
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.
CVE-2018-7784 1 Schneider-electric 1 U.motion 2024-11-21 N/A
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.
CVE-2018-7783 1 Schneider-electric 1 Somachine Basic 2024-11-21 N/A
Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is triggered when input passed to the xml parser is not sanitized while parsing the xml project/template file.
CVE-2018-7782 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2024-11-21 N/A
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
CVE-2018-7781 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2024-11-21 N/A
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.