Search Results (323 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-41245 1 Vmware 3 Aria Operations, Cloud Foundation, Tools 2026-04-15 4.9 Medium
VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations.
CVE-2025-2129 2026-04-15 5.6 Medium
A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2025-1863 2026-04-15 9.8 Critical
Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2023-31325 1 Amd 6 Radeon, Radeon Pro W7000, Radeon Rx 7000 and 3 more 2026-04-15 7.2 High
Improper isolation of shared resources on System-on-a-chip (SOC) could a privileged attacker to tamper with the contents of the PSP reserved DRAM region potentially resulting in loss of confidentiality and integrity.
CVE-2024-2912 1 Bentoml 1 Bentoml 2026-04-15 10 Critical
An insecure deserialization vulnerability exists in the BentoML framework, allowing remote code execution (RCE) by sending a specially crafted POST request. By exploiting this vulnerability, attackers can execute arbitrary commands on the server hosting the BentoML application. The vulnerability is triggered when a serialized object, crafted to execute OS commands upon deserialization, is sent to any valid BentoML endpoint. This issue poses a significant security risk, enabling attackers to compromise the server and potentially gain unauthorized access or control.
CVE-2024-34063 2026-04-15 2.5 Low
vodozemac is an implementation of Olm and Megolm in pure Rust. Versions 0.5.0 and 0.5.1 of vodozemac have degraded secret zeroization capabilities, due to changes in third-party cryptographic dependencies (the Dalek crates), which moved secret zeroization capabilities behind a feature flag and defaulted this feature to off. The degraded zeroization capabilities could result in the production of more memory copies of encryption secrets and secrets could linger in memory longer than necessary. This marginally increases the risk of sensitive data exposure. This issue has been addressed in version 0.6.0 and users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-48122 2026-04-15 6.7 Medium
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges.
CVE-2025-62877 1 Suse 1 Harvester 2026-04-15 9.8 Critical
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password  if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.
CVE-2024-51758 1 Filament 1 Excel Export 2026-04-15 N/A
Filament is a collection of full-stack components for accelerated Laravel development. All Filament features that interact with storage use the `default_filesystem_disk` config option. This allows the user to easily swap their storage driver to something production-ready like `s3` when deploying their app, without having to touch multiple configuration options and potentially forgetting about some. The default disk is set to `public` when you first install Filament, since this allows users to quickly get started developing with a functional disk that allows features such as file upload previews locally without the need to set up an S3 disk with temporary URL support. However, some features of Filament such as exports also rely on storage, and the files that are stored contain data that should often not be public. This is not an issue for the many deployed applications, since many use a secure default disk such as S3 in production. However, [CWE-1188](https://cwe.mitre.org/data/definitions/1188.html) suggests that having the `public` disk as the default disk in Filament is a security vulnerability itself. As such, we have implemented a measure to protect users whereby if the `public` disk is set as the default disk, the exports feature will automatically swap it out for the `local` disk, if that exists. Users who set the default disk to `local` or `s3` already are not affected. If a user wants to continue to use the `public` disk for exports, they can by setting the export disk deliberately. This change has been included in the 3.2.123 release and all users who use the `public` disk are advised to upgrade.
CVE-2024-8313 2026-04-15 N/A
An Exposure of Sensitive System Information to an Unauthorized Control Sphere and Initialization of a Resource with an Insecure Default vulnerability in the SNMP component of B&R APROL <4.4-00P5 may allow an unauthenticated adjacent-based attacker to read and alter configuration using SNMP.
CVE-2025-14758 1 Alasca 1 Yaook 2026-04-15 6.5 Medium
Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials
CVE-2025-61481 1 Mikrotik 2 Routeros, Switchos 2026-04-15 10 Critical
An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-59097 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet.
CVE-2025-52622 1 Hcltech 1 Bigfix Saas 2026-04-15 5.4 Medium
The BigFix SaaS's HTTP responses were missing some security headers. The absence of these headers weakens the application's client-side security posture, making it more vulnerable to common web attacks that these headers are designed to mitigate, such as Cross-Site Scripting (XSS), Clickjacking, and protocol downgrade attacks.
CVE-2025-54514 1 Amd 10 Epyc 9005 Series Processors, Epyc Embedded 9005 Series Processors, Ryzen 5000 Series Desktop Processors and 7 more 2026-04-15 N/A
Improper isolation of shared resources on a system on a chip by a malicious local attacker with high privileges could potentially lead to a partial loss of integrity.
CVE-2025-59090 1 Dormakaba 1 Kaba Exos 9300 2026-04-15 N/A
On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.