Search Results (282 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-6043 1 Perforce 1 Helix Core Server P4d 2026-04-28 N/A
P4 Server versions prior to 2026.1 are configured with insecure default settings that, when exposed to untrusted networks, allow unauthenticated attackers to create arbitrary user accounts, enumerate existing users, authenticate to accounts with no password set, and access depot contents via the built-in 'remote' user. These default settings, taken together, can lead to unauthorized access to source code repositories and other managed assets. The 2026.1 release, expected in May 2026, enforces secure-by-default configurations on upgrade and new installations
CVE-2026-41679 1 Paperclip 3 Paperclipai, Paperclipai/server, Paperclipai\/server 2026-04-28 10 Critical
Paperclip is a Node.js server and React UI that orchestrates a team of AI agents to run a business. Prior to version 2026.416.0, an unauthenticated attacker can achieve full remote code execution on any network-accessible Paperclip instance running in `authenticated` mode with default configuration. No user interaction, no credentials, just the target's address. The chain consists of six API calls. The attack is fully automated, requires no user interaction, and works against the default deployment configuration. Version 2026.416.0 patches the issue.
CVE-2026-39920 1 Bridgehead Software 1 Filestore 2026-04-27 9.8 Critical
BridgeHead FileStore versions prior to 24A (released in early 2024) expose the Apache Axis2 administration module on network-accessible endpoints with default credentials that allows unauthenticated remote attackers to execute arbitrary OS commands. Attackers can authenticate to the admin console using default credentials, upload a malicious Java archive as a web service, and execute arbitrary commands on the host via SOAP requests to the deployed service.
CVE-2026-32965 1 Silextechnology 3 Amc Manager, Sd-330ac, Sd-330ac Firmware 2026-04-22 7.5 High
Initialization of a resource with an insecure default vulnerability exists in SD-330AC and AMC Manager provided by silex technology, Inc. When the affected device is connected to the network with the initial (factory-default) configuration, the device can be configured with the null string password.
CVE-2025-13357 1 Hashicorp 1 Terraform Provider 2026-04-20 7.4 High
Vault’s Terraform Provider incorrectly set the default deny_null_bind parameter for the LDAP auth method to false by default, potentially resulting in an insecure configuration. If the underlying LDAP server allowed anonymous or unauthenticated binds, this could result in authentication bypass. This vulnerability, CVE-2025-13357, is fixed in Vault Terraform Provider v5.5.0.
CVE-2026-2617 1 Beetel 2 777vr1, 777vr1 Firmware 2026-04-18 6.3 Medium
A vulnerability was found in Beetel 777VR1 up to 01.00.09. This affects an unknown function of the component Telnet Service/SSH Service. The manipulation results in insecure default initialization of resource. The attack can only be performed from the local network. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-25499 1 Bpg 2 Terraform-provider-proxmox, Terraform Provider 2026-04-17 7.5 High
Terraform / OpenTofu Provider adds support for Proxmox Virtual Environment. Prior to version 0.93.1, in the SSH configuration documentation, the sudoer line suggested is insecure and can result in escaping the folder using ../, allowing any files on the system to be edited. This issue has been patched in version 0.93.1.
CVE-2026-25894 1 Frangoteam 1 Fuxa 2026-04-17 9.8 Critical
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. An insecure default configuration in FUXA allows an unauthenticated, remote attacker to gain administrative access and execute arbitrary code on the server. This affects FUXA through version 1.2.9 when authentication is enabled, but the administrator JWT secret is not configured. This issue has been patched in FUXA version 1.2.10.
CVE-2026-28775 2 Datacast, International Datacasting Corporation (idc) 3 Sfx2100, Sfx2100 Firmware, Sfx2100 Series Superflex Satellitereceiver 2026-04-17 9.8 Critical
An unauthenticated Remote Code Execution (RCE) vulnerability exists in the SNMP service of International Datacasting Corporation (IDC) SFX Series SuperFlex SatelliteReceiver. The deployment insecurely provisions the `private` SNMP community string with read/write access by default. Because the SNMP agent runs as root, an unauthenticated remote attacker can utilize `NET-SNMP-EXTEND-MIB` directives, abusing the fact that the system runs a vulnerable version of net-snmp pre 5.8, to execute arbitrary operating system commands with root privileges.
CVE-2026-1675 1 Wordpress 1 Wordpress 2026-04-15 5.3 Medium
The Advanced Country Blocker plugin for WordPress is vulnerable to Authorization Bypass in all versions up to, and including, 2.3.1 due to the use of a predictable default value for the secret bypass key created during installation without requiring users to change it. This makes it possible for unauthenticated attackers to bypass the geolocation blocking mechanism by appending the key to any URL on sites where the administrator has not changed the default value.
CVE-2026-26122 1 Microsoft 2 Aci Confidential Containers, Microsoft Aci Confidential Containers 2026-04-15 6.5 Medium
Initialization of a resource with an insecure default in Azure Compute Gallery allows an authorized attacker to disclose information over a network.
CVE-2026-34780 2 Electron, Electronjs 2 Electron, Electron 2026-04-15 8.4 High
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From versions 39.0.0-alpha.1 to before 39.8.0, 40.0.0-alpha.1 to before 40.7.0, and 41.0.0-alpha.1 to before 41.0.0-beta.8, apps that pass VideoFrame objects (from the WebCodecs API) across the contextBridge are vulnerable to a context isolation bypass. An attacker who can execute JavaScript in the main world (for example, via XSS) can use a bridged VideoFrame to gain access to the isolated world, including any Node.js APIs exposed to the preload script. Apps are only affected if a preload script returns, resolves, or passes a VideoFrame object to the main world via contextBridge.exposeInMainWorld(). Apps that do not bridge VideoFrame objects are not affected. This issue has been patched in versions 39.8.0, 40.7.0, and 41.0.0-beta.8.
CVE-2018-25193 1 Cesanta 1 Mongoose Web Server 2026-04-15 7.5 High
Mongoose Web Server 6.9 contains a denial of service vulnerability that allows remote attackers to crash the service by establishing multiple socket connections. Attackers can repeatedly create connections to the default port and send malformed data to exhaust server resources and cause service unavailability.
CVE-2018-25169 2 Ampps, Softaculous 2 Ampps, Ampps 2026-04-15 7.5 High
AMPPS 2.7 contains a denial of service vulnerability that allows remote attackers to crash the service by sending malformed data to the default HTTP port. Attackers can establish multiple socket connections and transmit invalid payloads to exhaust server resources and cause service unavailability.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-2129 2026-04-15 5.6 Medium
A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it.
CVE-2025-1863 2026-04-15 9.8 Critical
Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2025-62877 1 Suse 1 Harvester 2026-04-15 9.8 Critical
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password  if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.
CVE-2024-48122 2026-04-15 6.7 Medium
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges.