Search Results (1699 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-35244 2026-04-15 9.1 Critical
There are several hidden accounts. Some of them are intended for maintenance engineers, and with the knowledge of their passwords (e.g., by examining the coredump), these accounts can be used to re-configure the device. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
CVE-2025-10609 1 Logo Software 1 Tigerwings Erp 2026-04-15 5.9 Medium
Use of Hard-coded Credentials vulnerability in Logo Software Inc. TigerWings ERP allows Read Sensitive Constants Within an Executable.This issue affects TigerWings ERP: from 01.01.00 before 3.03.00.
CVE-2021-47744 2 Cypress, Linux 3 Ctm-200, Ctm-one, Linux 2026-04-15 7.5 High
Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices.
CVE-2024-5514 1 Minmax 1 Minmax 2026-04-15 9.8 Critical
MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs.
CVE-2025-26410 2026-04-15 9.8 Critical
The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1.
CVE-2025-5023 2026-04-15 7.1 High
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020.
CVE-2024-33329 1 Lumis 1 Lumis Experience Platform 2026-04-15 7.5 High
A hardcoded privileged ID within Lumisxp v15.0.x to v16.1.x allows attackers to bypass authentication and access internal pages and other sensitive information.
CVE-2025-9380 1 Fnkvision 1 Y215 Cctv Camera 2026-04-15 7.8 High
A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-46505 2026-04-15 9.1 Critical
Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities.
CVE-2024-28146 2026-04-15 8.4 High
The application uses several hard-coded credentials to encrypt config files during backup, to decrypt the new firmware during an update and some passwords allow a direct connection to the database server of the affected device.
CVE-2020-37092 1 Netis-systems 1 Netis E1+ 2026-04-15 7.5 High
Netis E1+ version 1.2.32533 contains a hardcoded root account vulnerability that allows unauthenticated attackers to access the device with predefined credentials. Attackers can leverage the embedded root account with a crackable password to gain full administrative access to the network device.
CVE-2024-8893 2026-04-15 7.3 High
Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1.
CVE-2025-4130 2026-04-15 7.5 High
Use of Hard-coded Credentials vulnerability in PAVO Inc. PAVO Pay allows Read Sensitive Constants Within an Executable.This issue affects PAVO Pay: before 13.05.2025.
CVE-2025-64766 2 Nixos, Onlyoffice 2 Nixos, Onlyoffice 2026-04-15 5.3 Medium
NixOS's Onlyoffice is a software suite that offers online and offline tools for document editing, collaboration, and management. In versions from 22.11 to before 25.05 and versions before Unstable 25.11, a hard-coded secret was used in the NixOS module for the OnlyOffice document server to protect its file cache. An attacker with knowledge of an existing revision ID could use this secret to obtain a document. In practice, an arbitrary revision ID should be hard to obtain. The primary impact is likely the access to known documents from users with expired access. This issue was resolved in NixOS unstable version 25.11 and version 25.05.
CVE-2025-2342 2026-04-15 5.3 Medium
A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-57790 2026-04-15 5.4 Medium
IXON B.V. IXrouter IX2400 (Industrial Edge Gateway) v3.0 was discovered to contain hardcoded root credentials stored in the non-volatile flash memory. This vulnerability allows physically proximate attackers to gain root access via UART or SSH.
CVE-2025-14096 1 Radiometer 5 Abl800 Basic Analyzer, Abl800 Flex Analyzer, Abl90 Flex Analyzer and 2 more 2026-04-15 8.4 High
A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.
CVE-2025-41380 2026-04-15 N/A
Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string.
CVE-2024-10451 1 Redhat 3 Build Keycloak, Jboss Enterprise Application Platform, Red Hat Single Sign On 2026-04-15 5.9 Medium
A flaw was found in Keycloak. This issue occurs because sensitive runtime values, such as passwords, may be captured during the Keycloak build process and embedded as default values in bytecode, leading to unintended information disclosure. In Keycloak 26, sensitive data specified directly in environment variables during the build process is also stored as a default values, making it accessible during runtime. Indirect usage of environment variables for SPI options and Quarkus properties is also vulnerable due to unconditional expansion by PropertyMapper logic, capturing sensitive data as default values in all Keycloak versions up to 26.0.2.
CVE-2017-20214 1 Flir 1 Thermal Camera 2026-04-15 7.5 High
FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.