| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of Hard-coded Credentials vulnerability in PAVO Inc. PAVO Pay allows Read Sensitive Constants Within an Executable.This issue affects PAVO Pay: before 13.05.2025. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| Hard-coded credentials were included as part of the application binary.
These credentials served as part of the application authentication flow
and communication with the mobile application. An attacker could access
unauthorized information. |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
| Use of hard-coded credentials issue exists in ZWX-2000CSW2-HN prior to 0.3.19 and ZWX-2000CS2-HN firmware all versions. If this vulnerability is exploited, an attacker may tamper with the settings of the device by obtaining the credentials. This vulnerability is caused by an insufficient fix for CVE-2024-39838. |
| A hardcoded AES key in PMFW may result in a privileged attacker gaining access to the key, potentially resulting in internal debug information leakage. |
| The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. |
| MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs. |
| Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string. |
| DCIM dcTrack platforms utilize default and hard-coded credentials for access. An attacker could use these credentials to administer the database, escalate privileges on the platform or execute system commands on the host. |
| HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access. |
| Allstar is a GitHub App to set and enforce security policies. In versions prior to 4.5, a vulnerability in Allstar’s Reviewbot component caused inbound webhook requests to be validated against a hard-coded, shared secret. The value used for the secret token was compiled into the Allstar binary and could not be configured at runtime. In practice, this meant that every deployment using Reviewbot would validate requests with the same secret unless the operator modified source code and rebuilt the component - an expectation that is not documented and is easy to miss. All Allstar releases prior to v4.5 that include the Reviewbot code path are affected. Deployments on v4.5 and later are not affected. Those who have not enabled or exposed the Reviewbot endpoint are not exposed to this issue. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to hard-coded Root Access Credentials in system configuration of the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to obtain the stored root access credentials.
Successful exploitation of this vulnerability could allow the attacker to gain admin access to the targeted device. |
| Ever Traduora 0.20.0 and below is vulnerable to Privilege Escalation due to the use of a hard-coded JWT signing key. |
| ui/pref/ProxyPrefView.java in weasis-core in Weasis 4.5.1 has a hardcoded key for symmetric encryption of proxy credentials. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| INIM Electronics Smartliving SmartLAN/G/SI <=6.x contains hard-coded credentials in its Linux distribution image that cannot be changed through normal device operations. Attackers can exploit these persistent credentials to log in and gain unauthorized system access across multiple SmartLiving device models. |
| Hardcoded credentials vulnerability in Trellix ePolicy Orchestrator (ePO) on Premise prior to 5.10 Service Pack 1 Update 2 allows an attacker with admin privileges on the ePO server to read the contents of the orion.keystore file, allowing them to access the ePO database encryption key. This was possible through using a hard coded password for the keystore. Access Control restrictions on the file mean this would not be exploitable unless the user is the system admin for the server that ePO is running on. |
| A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable. |
| The WP2Speed Faster – Optimize PageSpeed Insights Score 90-100 plugin for WordPress is vulnerable to unauthorized access in all versions up to, and including, 1.0.1. This is due to the use of hardcoded credentials to authenticate all the incoming API requests. This makes it possible for unauthenticated attackers to overwrite CSS, update the trial settings, purge the cache, and find attachments. |